PRODUCTS

Coefficient of heat loss
Panel thicknessTrasmittance
EN UNI 14509
Trasmittance
(8 days)
(mm)U=W/m2KU=W/m2K
250,820,75
300,700,64
350,610,55
400,530,49
500,430,39
600,360,33
800,270,25
1000,220,20
1200,180,16
1400,160,14
1500,150,13
1600,140,12
1800,120,11
2000,110,10

Contacts & Market

Contact us for information and requests.

Customer Care

    FOAMWALL A2

    Dimensions

    width mm 1000

    length upon request from continuous production process.

    Thicknesses (S)

    mm 25 -30 - 35 - 40 - 50 - 60 - 80 - 100 - 120 - 140 - 150 - 160 - 180 - 200 panels of non standard thicknesses can be supplied upon request previous agreement on minimum quantities (max. mm 200).

    Supports

    galvanized steel, galvanized prepainted or plastified steel; stainless steel; natural or prepainted aluminium; copper (CORAM).

    Insulation through continuous foaming process

    Polyurethane resins (PUR) and (not standard) polyisocianurate foams (PIR), density 39 ±2 Kg/m³ Declared value of thermal transmittance for a panel after 25 years of its installation, (Appendix C - EN 13165) Initial value of thermal conductivity: λ = 0.020 W/(mK)

    Protective treatments for external support available

    On request for external polyester coating, atoxic prepainted for food contact, silicone polyester, PVDF, thermoplastic Class A application of PVC plastic films or other films

    Insights PIR foam

    On request is available in PIR foam version (polyisocyanurate), a particular polymeric structure that guarantees excellent characteristics of fire behavior. The entire range of ISOLPACK panels has been certified in Class B-s2, d0 at CSTB (France) and at KIT (Germany) in compliance with UNI EN 13823 (SBI) * where, "B" expresses the quantity of heat produced during the first 600 seconds of the test <7.5 MJ (best value obtainable for foamed products); "S2" represents a very low development of the fumes and "d0" indicates the absolute absence of drops and/or inflamed particles. In last years, the SBI test has become a standard requirement in Europe for fire behavior of building materials. The new European standard for sandwich panels - UNI EN 14509 - uses the SBI system for fire classification purposes. ISOLPACK is the only one in Italy to design light, highly insulating applications with unequaled fire reaction requirements. In many cases it can replace the rock wool panel considering its fire reaction characteristics combined with the very high thermal insulation power.

    EPD certification (CAM)

    CAM available.
    For more information on CAM certification, contact the technical / commercial department.

    LOADS TABLE

    PITCH BETWEEN SUPP.(m)
    PANEL TICKNESS(mm)
    SHEET TICKNESS(mm)
    MATERIAL
    MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION *
    Panel
    Thickness
    (mm)
    MaterialSheet
    thickness
    (mm)
    Pitch 'L' in meters between the supports
    1,50 2,00 2,50 3,00 3,50 4,00 4,50 5,00 5,50 6,00
    25ACCIAIO0,4 + 0,4
    30ACCIAIO0,4 + 0,4 237 171 103 66 44 31 22 17 13 10
    35ACCIAIO0,4 + 0,4 275 200 132 87 60 41 30 23 17 12
    40ALLUMINIO0,4 + 0,4
    40ACCIAIO0,4 + 0,4 317 238 163 107 74 52 38 29 22 17
    50ALLUMINIO0,4 + 0,4
    50ACCIAIO0,4 + 0,4 397 298 230 154 108 77 57 43 34 26
    60ALLUMINIO0,4 + 0,4
    60ACCIAIO0,4 + 0,4 477 358 286 206 146 106 79 60 47 37
    80ALLUMINIO0,4 + 0,4
    80ACCIAIO0,4 + 0,4 637 478 382 292 214 164 130 101 79 63
    100ALLUMINIO0,4 + 0,4
    100ACCIAIO0,4 + 0,4 709 531 425 354 268 205 162 131 109 91
    120ALLUMINIO0,4 + 0,4
    120ACCIAIO0,4 + 0,4 851 638 510 425 322 246 195 158 130 109
    140ALLUMINIO0,4 + 0,4
    140ACCIAIO0,4 + 0,4 993 745 596 496 376 288 227 184 152 128
    150ACCIAIO0,4 + 0,4 1064 798 638 532 402 308 243 197 163 137
    160ACCIAIO0,4 + 0,4 1135 851 681 568 429 329 260 210 174 146
    180ACCIAIO0,4 + 0,4 1277 958 766 639 483 370 292 237 196 164
    200ACCIAIO0,4 + 0,4 1420 1065 852 710 537 411 325 263 217 183
    MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION *
    Panel
    Thickness
    (mm)
    MaterialSheet
    thickness
    (mm)
    Pitch 'L' in meters between the supports
    1,50 2,00 2,50 3,00 3,50 4,00 4,50 5,00 5,50 6,00
    25ACCIAIO0,4 + 0,4
    30ACCIAIO0,4 + 0,420415112096684937282217
    35ACCIAIO0,4 + 0,4240176140110896449382923
    40ALLUMINIO0,4 + 0,4
    40ACCIAIO0,4 + 0,42752031611341088060473629
    50ALLUMINIO0,4 + 0,4
    50ACCIAIO0,4 + 0,434625520216814311387685443
    60ALLUMINIO0,4 + 0,4
    60ACCIAIO0,4 + 0,4419308244202173137107867059
    80ALLUMINIO0,4 + 0,4
    80ACCIAIO0,4 + 0,45654153282712311851841169579
    100ALLUMINIO0,4 + 0,4
    100ACCIAIO0,4 + 0,4634465367303258225183146120100
    120ALLUMINIO0,4 + 0,4
    120ACCIAIO0,4 + 0,4767562442365311271223178145121
    140ALLUMINIO0,4 + 0,4
    140ACCIAIO0,4 + 0,4884654515428364317264210171142
    150ACCIAIO0,4 + 0,4885655519430367320282226184153
    160ACCIAIO0,4 + 0,4887656520431367321284243197164
    180ACCIAIO0,4 + 0,4892658522435372325288246200170
    200ACCIAIO0,4 + 0,4895661525438375328291247201171