Coefficient of heat loss
Panel thicknessTrasmittance
EN UNI 14509
Trasmittance
(8 days)
(mm)U=W/m2KU=W/m2K
1200,180,16
1500,150,13
2000,110,10

Contacts & Market

Contact us for information and requests.

Customer Care

    ALFA KING

    Dimensions

    width mm 1.155

    useful step mm 1.000

    length upon request from continuous production process.

    Thicknesses (S)

    mm 120 - 150 - 200 panels of non standard thicknesses can be supplied upon request previous agreement on minimum quantities.

    Supports

    FE S250GD galvanized steel, pre-painted or plastic-coated galvanized steel, stainless steel.

    Insulation through continuous foaming process

    Polyurethane resins (PUR) and (not standard) polyisocianurate foams (PIR), density 39 ±2 Kg/m³ Declared value of thermal transmittance for a panel after 25 years of its installation, (Appendix C - EN 13165) Initial value of thermal conductivity: λ = 0.020 W/(mK)

    Protective treatments for external support available

    On request for external polyester coating, atoxic prepainted for food contact, silicone polyester, PVDF, thermoplastic Class A application of PVC plastic films or other films.

    EPD certification (CAM)

    The entire range of roofing and wall panels in steel and aluminium in PIR, PUR and mineral wool, single metal sheet panels and corrugated metal sheets in steel and aluminium, possess the EPD type III - EN ISO 14025 certification, meeting the requirements of compliance with the regulation construction DM 23 June 2022, and satisfying the required CAM criteria.

    Insights PIR foam

    On request is available in PIR foam version (polyisocyanurate), a particular polymeric structure that guarantees excellent characteristics of fire behavior. The entire range of ISOLPACK panels has been certified in Class B-s2, d0 at CSTB (France) and at KIT (Germany) in compliance with UNI EN 13823 (SBI) * where, "B" expresses the quantity of heat produced during the first 600 seconds of the test <7.5 MJ (best value obtainable for foamed products); "S2" represents a very low development of the fumes and "d0" indicates the absolute absence of drops and/or inflamed particles. In last years, the SBI test has become a standard requirement in Europe for fire behavior of building materials. The new European standard for sandwich panels - UNI EN 14509 - uses the SBI system for fire classification purposes. ISOLPACK is the only one in Italy to design light, highly insulating applications with unequaled fire reaction requirements. In many cases it can replace the rock wool panel considering its fire reaction characteristics combined with the very high thermal insulation power.

    LOADS TABLE

    PITCH BETWEEN SUPP.(m)
    PANEL TICKNESS(mm)
    SHEET TICKNESS(mm)
    MATERIAL
    MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION *
    Panel
    Thickness
    (mm)
    MaterialSheet
    thickness
    (mm)
    Pitch 'L' in meters between the supports
    3,00 3,50 4,00 4,50 5,00 5,50 6,00
    120ALLUMINIO0,5 + 0,5
    120ACCIAIO0,5 + 0,5 559 411 315 249 201 161 130
    150ACCIAIO0,5 + 0,5 700 514 393 311 252 208 175
    200ACCIAIO0,5 + 0,5 763 608 525 415 336 278 233