PRODUCTS

Coefficient of heat loss
Panel thicknessTrasmittance
EN UNI 14509
Trasmittance
(8 days)
(mm)U=W/m2KU=W/m2K
300,690,64
400,530,49
500,430,40

Contacts & Market

Contact us for information and requests.

Customer Care

    ISOLPACK R4

    pannello sandwich

    Dimensions

    width mm 1000

    length upon request from continuous production process.

    Thicknesses (S)

    mm 30 - 40 - 50 panels of non standard thicknesses can be supplied upon request previous agreement on minimum quantities.

    Supports

    galvanized steel, galvanized prepainted or plastified steel; stainless steel; natural or prepainted aluminium; copper (CORAM).

    Insulation through continuous foaming process

    Polyurethane resins (PUR) and (not standard) polyisocianurate foams (PIR), density 39 ±2 Kg/m³ Declared value of thermal transmittance for a panel after 25 years of its installation, (Appendix C - EN 13165) Initial value of thermal conductivity: λ = 0.020 W/(mK)

    Protective treatments for external support available

    On request for external polyester coating, atoxic prepainted for food contact, silicone polyester, PVDF, thermoplastic Class A application of PVC plastic films or other films

    Insights PIR foam

    On request is available in PIR foam version (polyisocyanurate), a particular polymeric structure that guarantees excellent characteristics of fire behavior. The entire range of ISOLPACK panels has been certified in Class B-s2, d0 at CSTB (France) and at KIT (Germany) in compliance with UNI EN 13823 (SBI) * where, "B" expresses the quantity of heat produced during the first 600 seconds of the test <7.5 MJ (best value obtainable for foamed products); "S2" represents a very low development of the fumes and "d0" indicates the absolute absence of drops and/or inflamed particles. In last years, the SBI test has become a standard requirement in Europe for fire behavior of building materials. The new European standard for sandwich panels - UNI EN 14509 - uses the SBI system for fire classification purposes. ISOLPACK is the only one in Italy to design light, highly insulating applications with unequaled fire reaction requirements. In many cases it can replace the rock wool panel considering its fire reaction characteristics combined with the very high thermal insulation power.

    EPD certification (CAM)

    The entire range of roofing and wall panels in steel and aluminium in PIR, PUR and mineral wool, single metal sheet panels and corrugated metal sheets in steel and aluminium, possess the EPD type III - EN ISO 14025 certification, meeting the requirements of compliance with the regulation construction DM 23 June 2022, and satisfying the required CAM criteria.

    LOADS TABLE

    PITCH BETWEEN SUPP.(m)
    PANEL TICKNESS(mm)
    SHEET TICKNESS(mm)
    MATERIAL
    MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION *
    Panel
    Thickness
    (mm)
    MaterialSheet
    thickness
    (mm)
    Pitch 'L' in meters between the supports
    1,50 2,00 2,50 3,00 3,50 4,00 4,50 5,00 5,50 6,00
    30ALLUMINIO0,5 + 0,5
    30ACCIAIO0,5 + 0,5 449 205 114 71 47 33 23 17 13 9
    40ALLUMINIO0,5 + 0,5
    40ACCIAIO0,5 + 0,5 508 244 143 93 65 47 35 26 20 16
    50ACCIAIO0,5 + 0,5 564 282 171 115 82 61 47 36 29 23
    MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION *
    Panel
    Thickness
    (mm)
    MaterialSheet
    thickness
    (mm)
    Pitch 'L' in meters between the supports
    1,50 2,00 2,50 3,00 3,50 4,00 4,50 5,00 5,50 6,00
    30ALLUMINIO0,5 + 0,5
    30ACCIAIO0,5 + 0,566448732322015912094756252
    40ALLUMINIO0,5 + 0,5
    40ACCIAIO0,5 + 0,5694509400286207156122988067
    50ACCIAIO0,5 + 0,57245314173432551921501209982

    SALES EUROPEAN ORGANIZATION SRL
    Corso Re Umberto, 5 Bis
    10121 Torino (TO)

    VAT n. 11862630016

     

    FR  | DE  | ES 